;Procedure: THM_CAL_FBK
;
;Purpose: Converts raw FBK (Filter Bank) data into physical quantities.
;keywords:
; probe = Probe name. The default is 'all', i.e., calibrate data for all
; available probes.
; This can be an array of strings, e.g., ['a', 'b'] or a
; single string delimited by spaces, e.g., 'a b'
; datatype = The type of data to be loaded, 'fbh', 'fb1', 'fb2'. default is
; 'all', to calibrate all variables.
; due to some last minute changes it is required that you include
; both the raw and the calibrated datatype you want for this function
; to perform properly
; in_suffix = optional suffix to add to name of input data quantity, which
; is generated from probe and datatype keywords.
; out_suffix = optional suffix to add to name for output tplot quantity,
; which is generated from probe and datatype keywords.
; /VALID_NAMES; returns the allowable input names in the probe and
; datatype variables
; /VERBOSE or VERBOSE=n ; set to enable diagnostic message output.
; higher values of n produce more and lower-level diagnostic messages.
;
;Example:
; thm_cal_fbk
;
;Notes:
; -- Changes between signal sources are handled;
; source info from HED data should be used to get actual units of a given spectrum.
; -- fixed, nominal calibration pars used (gains and frequency responses), rather than proper time-dependent parameters.
;--must include raw types in datatype input for calibration to
;work properly(hopefully will be fixed post-release)
;--support data must be loaded to function properly
; $LastChangedBy: pcruce $
; $LastChangedDate: 2007-07-16 17:29:00 -0700 (Mon, 16 Jul 2007) $
; $LastChangedRevision: 1123 $
; $URL $
;-
pro thm_cal_fbk, probe=probe, datatype=datatype,trange=trange, $
in_suffix = in_suffix,out_suffix = out_suffix, valid_names=valid_names,$
verbose = verbose
thm_init
vprobes = ['a','b','c','d','e']
fbk_sel_str = [ 'v1', 'v2', 'v3', 'v4', 'v5', 'v6','edc12', 'edc34', 'edc56', $
'scm1', 'scm2', 'scm3', 'eac12', 'eac34', 'eac56' ]
fbk_valid_raw = 'fb'+['1', '2', 'h']
fbk_valid_names = ssl_set_union('fb_'+ [fbk_sel_str,'hff'], fbk_valid_raw)
if not keyword_set(in_suffix) then in_suffix = ''
if not keyword_set(out_suffix) then out_suffix = ''
if arg_present( valid_names) then begin
probe = vprobes
datatype = fbk_valid_names
message, /info, string( strjoin( fbk_valid_names, ','), format='( "Valid names:",X,A,".")')
return
endif
;probe validation
if not keyword_set(probe) then probe = vprobes $
else vprobes = thm_check_valid_name(strlowcase(probe), vprobes, /include_all)
if not keyword_set(probe) then return
if keyword_set(verbose) then print, probe
;datatype validation
if not keyword_set(datatype) then dts = fbk_valid_names $
else dts = thm_check_valid_name(strlowcase(datatype), fbk_valid_names, /include_all)
if keyword_set(verbose) then printdat, dts, /value, 'Datatypes'
for s=0L,n_elements(probe)-1L do begin
sc = probe[s]
;only requested raw datatypes are used in this loop
dtl = ssl_set_intersection(dts, fbk_valid_raw)
if(size(dtl, /n_dim) eq 0) then return
for n=0L, n_elements( dtl)-1L do begin
name = dtl[ n]
tplot_var = thm_tplot_var( sc, name)
;if data is already calibrated skip this iteration
if thm_data_calibrated(tplot_var+in_suffix) then continue
get_data, tplot_var+in_suffix, data=d, limit=l, dlim=dl
; default behavior is to preserve the RAW data under a different TPLOT variable name.
;if not keyword_set( discard_raw) then begin
; str_element, dl, 'data_type', 'raw', /add
; tplot_var_raw = string( tplot_var, 'raw', format='(A,"_",A)')
; store_data, tplot_var_raw, data=d, limit=l, dlimit=dl
;endif
; handle regular FB and HF channels differently.
switch strlowcase( name) of
'fb1':
'fb2': begin
tplot_var_src = tplot_var + '_src'
get_data, tplot_var_src, data=d_src, limit=l_src, dlim=dl_src
; check that returned data and hed structures are structures (get_data returns 0 if no TPLOT variable exists).
if (size( d, /type) eq 8) and (size( d_src, /type) eq 8) then begin
;used for calculating size of the result set array
res_size = size(d.y, /dimensions)
; Determine what signal sources were selected over the given time interval,
; and apply the appropriate RAW->PHYS conversion factors.
fb_sel = d_src.y
find_const_intervals, fb_sel, nint=nint, ibeg=ibeg, iend=iend
if(nint gt 0) then begin
;an array holding the data from each interval
res_arr = fltarr([res_size[0:1], nint]) + !values.f_nan
;a list of the sources for each interval
sel_list = fltarr(nint)
;this call just gets the definition of cal_pars
thm_get_fbk_cal_pars,0,0,1,cal_pars=cp_def
;this constructs an array of cal pars structs
cp_list = replicate(cp_def,nint)
endif
for ii=0L,nint-1L do begin
t_hdr = [ d_src.x, !values.d_infinity]
tbeg = t_hdr[ ibeg[ ii]]
tend = t_hdr[ iend[ ii] + 1L]
; find all the spectra from the beginning of the first packet of the interval,
; to the end of the last packet of the interval
; (actually just before the beginning of the first packet of the next interval).
idx = where( d.x ge tbeg and d.x lt tend, icnt)
if icnt gt 0 then begin
thm_get_fbk_cal_pars, tbeg, tend, fb_sel[ ibeg[ ii]], cal_pars=cp
res_arr[ idx, *, ii] = cp.gain*((1.0 + fltarr( icnt))#cp.freq_resp[ *])*(thm_fbk_decompress(d.y[ idx, *]))
sel_list[ii] = fb_sel[ibeg[ii]]
cp_list[ii]=cp
endif
endfor ; loop over constant source intervals.
;interval collation handles a very rare case of instrument
;reconfiguration
out_data = thm_collate_intervals(res_arr, sel_list)
sel = thm_get_unique_sel(sel_list, fbk_sel_str)
cp = thm_get_unique_cp(sel_list,fbk_sel_str,cp_list)
;loop over collated sources
for i = 0, n_elements(sel)-1L do begin
units = '<|nT|>,<|V|>, or <|mV/m|>'
out_name = 'th' + sc + '_fb_' + sel[i] + out_suffix
; update the DLIMIT elements to reflect RAW->PHYS transformation, coordinate system, etc.
str_element, dl, 'data_att', data_att, success = has_data_att
if has_data_att then begin
str_element, data_att, 'data_type', 'calibrated', /add
endif else data_att = { data_type: 'calibrated' }
str_element, data_att, 'coord_sys', 'sensor', /add
str_element, data_att, 'units', cp.units, /add
str_element, data_att, 'cal_par_time', cp.cal_par_time, /add
str_element, data_att, 'source_var', tplot_var, /add
str_element, dl, 'data_att', data_att, /add
str_element, dl, 'ytitle', string( out_name+out_suffix, units, format = '(A,"!C!C[",A,"]")'), /add
str_element, dl, 'labels', [ '3 Hz', '12 Hz', '48 Hz', '192 Hz', '768 Hz', '3072 Hz'], /add
str_element, dl, 'labflag', 1, /add
str_element, dl, 'colors', [ 1, 2, 3, 4, 5, 6]
; store the transformed spectra back into the original TPLOT variable.
foo = where(dts eq ('fb_'+ sel[i]), bar)
if(bar eq 1) then store_data, out_name, $
data = { x:d.x, y:out_data[*, *, i], v:d.v }, $
lim = l, dlim = dl
endfor
endif else begin ; necessary TPLOT variables not present.
if keyword_set(verbose) then $
message, /info, $
string( tplot_var+in_suffix, tplot_var_src, $
format='("necessary TPLOT variables (",A,X,A,") not present for RAW->PHYS transformation.")')
endelse
break
end ; end of { FB1, FB2} calibration clause.
'fbh': begin ; FBH (HF or AKR band filter).
; check that returned data and hed structures are structures (get_data returns 0 if no TPLOT variable exists).
if (size( d, /type) eq 8) then begin
cp = { $
gain:1.0, freq_resp:3.0, units:'V [100-400 kHz]', $
offset:222.13, slope: 22.58, $
cal_par_time:'2002-01-01:00:00:00' $
}
; convert digital log-amp output to differential volts at input to V1-V2.
res = exp((float(d.y)-cp.offset)/cp.slope)
; convert differential volts at input to V1-V2 to differential volts, sphere1-sphere2.
res = cp.gain*cp.freq_resp*res
; update the DLIMIT elements to reflect RAW->PHYS transformation, coordinate system, etc.
units = 'V [100-400 kHz]'
str_element, dl, 'data_att', data_att, success = has_data_att
if has_data_att then begin
str_element, data_att, 'data_type', 'calibrated', /add
endif else data_att = { data_type: 'calibrated' }
str_element, data_att, 'coord_sys', 'sensor', /add
str_element, data_att, 'units', units, /add
str_element, data_att, 'cal_par_time', cp.cal_par_time, /add
str_element, dl, 'data_att', data_att, /add
str_element, dl, 'ytitle', string( 'th'+sc+'_fb_hff'+out_suffix, units, format='(A,"!C!C[",A,"]")'), /add
str_element, dl, 'labels', [ 'avg', 'pk'], /add
str_element, dl, 'labflag', 1, /add
str_element, dl, 'colors', [ 1, 2]
; store the transformed spectra back into the original TPLOT variable.
foo = where(dts eq ('fb_hff'), bar)
if(bar eq 1) then $
store_data, 'th'+sc+'_fb_hff'+out_suffix, $
data = { x:d.x, y:res, v:d.v }, $
lim = l, dlim = dl
endif else begin ; necessary TPLOT variables not present.
if keyword_set(verbose) then $
message, /info, $
string( tplot_var+in_suffix, $
format='("necessary TPLOT variable (",A,") not present for RAW->PHYS transformation.")')
endelse
break
end
else: begin ; improperly defined name of FBK quantity.
end
endswitch
endfor ; loop over datatypes.
endfor ; loop over spacecraft.
end