This page was created by the IDL library routine
mk_html_help2
.
Last modified: Wed Dec 20 10:37:44 2023.
Read the angles between Bx mGSE and y and z axes in deg. Save to rbspx_angle_spinplane_Bo.
(See general/missions/rbsp/efw/rbsp_phasef/efw_flag/rbsp_efw_phasef_read_angle_spinplane_bo.pro)
Read autobias flag. time. The time range in unix time. probe=. 'a' or 'b'. local_root=. The local root directory for saving rbsp data. remote_root=. The URL for grabing rbsp data. version=. Default is 'v01'.
(See general/missions/rbsp/efw/rbsp_phasef/efw_flag/rbsp_efw_phasef_read_autobias_flag.pro)
Generate daily flag for autobias. AutoBias starts actively controlling the bias currents at V12 = -1.0 V, ramping down the magnitude of the bias current so that when V12 = 0.0 V, the bias current is very near to zero after starting out around -20 nA/sensor. For V12 > 0.0 V, the bias current continues to increase (become more positive), although at a slower rate, 0.2 nA/V or something like that. Auto Bias flag values. From 'rbsp?_efw_hsk_idpu_fast_TBD' Bit Value Meaning 3 8 Toggles off and on every other cycle when AutoBias is active. 2 4 One when AutoBias is controlling the bias, Zero when AutoBias is not controlling the bias. 1 2 One when BIAS3 and BIAS4 can be controlled by AUtoBias, zero otherwise. 0 1 One when BIAS1 and BIAS2 can be controlled by AUtoBias, zero otherwise.
(See general/missions/rbsp/efw/rbsp_phasef/efw_flag/rbsp_efw_phasef_read_autobias_flag_gen_file.pro)
Read the ratios of By/Bx and Bz/Bx in mGSE. Save to rbspx_diagBratio.
(See general/missions/rbsp/efw/rbsp_phasef/efw_flag/rbsp_efw_phasef_read_diagbratio.pro)
Get the 20-element flag_all for a certain boom pair.
(See general/missions/rbsp/efw/rbsp_phasef/efw_flag/rbsp_efw_phasef_read_flag_20.pro)
Get the 25-element flag_all for a certain boom pair.
(See general/missions/rbsp/efw/rbsp_phasef/efw_flag/rbsp_efw_phasef_read_flag_25.pro)
Apply wake effect correction to e_uvw.
(See general/missions/rbsp/efw/rbsp_phasef/efw_flag/rbsp_efw_phasef_read_wake_flag_gen_file.pro)
Read RBSP boom flag, where 1 is for working boom. time. A time or a time range in ut time. Set time to find files automatically, or set files to read data in them directly. id=. A string sets the data type to read. Check supported ids by setting print_datatype. print_datatype=. A boolean. Set to print all supported ids. probe=. A string set the probe to read data for. local_root=. A string to set the local root directory. remote_root=. A string to set the remote root directory. version=. A string to set specific version of files. By default, the program finds the files of the highest version.
(See general/missions/rbsp/efw/rbsp_phasef/efw_flag/rbsp_efw_read_boom_flag.pro)
Read all efw flags. time. The time range in unix time. probe=. 'a' or 'b'. local_root=. The local root directory for saving rbsp data. remote_root=. The URL for grabing rbsp data. version=. Default is 'v01'.
(See general/missions/rbsp/efw/rbsp_phasef/efw_flag/rbsp_efw_read_flags.pro)
Read all flags for all boom_pairs. Adopted from rbsp_efw_get_flag_values.
(See general/missions/rbsp/efw/rbsp_phasef/efw_flag/rbsp_efw_read_flags_gen_file.pro)
Generate daily flag for autobias. AutoBias starts actively controlling the bias currents at V12 = -1.0 V, ramping down the magnitude of the bias current so that when V12 = 0.0 V, the bias current is very near to zero after starting out around -20 nA/sensor. For V12 > 0.0 V, the bias current continues to increase (become more positive), although at a slower rate, 0.2 nA/V or something like that. Auto Bias flag values. From 'rbsp?_efw_hsk_idpu_fast_TBD' Bit Value Meaning 3 8 Toggles off and on every other cycle when AutoBias is active. 2 4 One when AutoBias is controlling the bias, Zero when AutoBias is not controlling the bias. 1 2 One when BIAS3 and BIAS4 can be controlled by AUtoBias, zero otherwise. 0 1 One when BIAS1 and BIAS2 can be controlled by AUtoBias, zero otherwise.
(See general/missions/rbsp/efw/rbsp_phasef/efw_flag/rbsp_gen_autobias_flag.pro)