ADC->EDEP boundaries

Patrick Cruce
pcruce@igpp.ucla.edu
Last Revision 2013-03-13

SST energy boundaries as configured on spacecraft.
Note that these numbers correspond to the energy deposition.
Not the incident energy of those particles.  Incident energy 
is modeled using GEANT4

ADC to KeV Conversion is: keV = adc*1.6+5.0 

////////////////////////////////////
O-OT-T has 15 channels
////////////////////////////////////
O-channel: 0x040,0x050,0x060,0x070
Boundaries(ADC): 12,19,26,34,44,69,103,150,215,306,506,906
Integral Channel at 906(906-4095)
Less than 12 is junk
Boundaries(keV): 24.2000, 35.4000, 46.6000, 59.4000, 75.4000, 115.400, 169.800, 245.000, 349.000, 494.600, 814.600, 1454.60, 6557.00(max)
/////////////////////////////////////
OT-channel,0x0C0,0x0D0,0x0E0,0x0F0
Boundaries: 2500, 4000
Integral Channel at 4000(4000-4095)
Less than 2500 is junk
Boundaries(keV):
4005.00, 6405.00, 6557.00(max)
/////////////////////////////////////
T-channel, 0x080,0x090,0x0A0,0x0B0
Boundaries: 0
Integral Channel at 0(0-4095)
Boundaries(keV): 0,6557.00(max)
/////////////////////////////////////
F-FT-FTO has 16 channels
/////////////////////////////////////
F-channel, 0x100,0x110,0x120,0x130
Boundaries: 12,19,26,34,44,69,103,150,215,306,506,906
Integral Channel at 906(906-4095)
Less than 12 is junk
Boundaries(keV): 24.2000, 35.4000, 46.6000, 59.4000, 75.4000, 115.400, 169.800, 245.000, 349.000, 494.600, 814.600, 1454.60, 6557.00(max)
/////////////////////////////////////
FT-channel, 0x180,0x190,0x1A0,0x1B0
Boundaries: 200, 300, 400
Less than 200 is junk
Above 499 is junk
Boundaries(keV):325.000, 485.000, 645.000, 803.400(max)
/////////////////////////////////////
FTO-channel,0x1C0,0x1D0,0x1E0,0x1F0
400-1199,2700-4096
Boundaries(keV) FTO_LOW: 645.00, 1923.40(max)
Boundaries(keV) FTO_HIGH: 4325.00, 6557(max)             
/////////////////////////////////////

How they are organized in data available on the ground:

Ion Bins:
0-11 = O
12-13 = OT
14 = T
15 = FTO(high)

Electron Bins:
0-11 = F
12-14 = FT
15 = FTO(low)